Your course

Pick up where you left off.

Current Status

Not Enrolled

Price

A$99.00

Get Started

Course Content

I. Introduction (3 min)
II. Learning Objectives (1 min)
III. Module 1: Where the Heat Actually Leaves (9 min)
IV. Module 2: What the Code Requires, and in Which Edition (12 min)
V. Module 3: Getting It Into the Model (10 min)
VI. Module 4: The Record, and the Conversation (8 min)
VII. Case Studies (3 min)
VIII. Summary and Key Takeaways (2 min)
Final Quiz – Thermal Bridging in Residential Design
For energy assessors, building designers and building surveyors

Thermal Bridging in Residential Design

When the drawings leave the frame blank, the assumption you make is the assessment.

Steel framing, junctions, and what the model does with an unspecified frame. Why a steel framed wall with the same batts as a timber one is a different building, when the metal framed wall and roof provisions actually require a thermal break, and how to model, request and record the frame so your assessment holds up at audit.

60 minutes, self-paced Intermediate level 1 formal CPD point Certificate on completion National, NCC 2025 and NCC 2022
Aligned to NSCA 2021 PC12 PC28 PC39 PC45 PC47
$99 inc. GST
  • Product neutral, no supplier content
  • Audio version and glossary included
  • Certificate saved to your dashboard

Secure card checkout. Tax invoice emailed.

Course content

4 modules, 2 case studies, final quiz and certificate.

Start 4 min

Introduction and objectives

Why steel framing turned bridging into everyday assessment work, and what you will be able to do by the end.

Module 1 9 min

Where the heat actually leaves

See why the path runs through the frame, not the batts, and why losses and mould gather at corners, openings and junctions.

Module 2 12 min

What the Code requires, and in which edition

Check the two conditions that trigger a thermal break, the R0.2 minimum and the sandwich panel exclusions, and cite the edition that governs.

Module 3 10 min

Getting it into the model

Model the frame you were given, handle a silent set, and check the slab edge, balcony and parapet before blaming the glazing.

Module 4 8 min

The record, and the conversation

Write a request for information that gets answered, keep an assumptions register, and answer pushback with a modelled comparison.

Case studies 3 min

A steel frame and a cathedral ceiling

A house that lost half a star when the frame changed to steel, and a raked ceiling that striped with mould.

Summary 2 min

Key takeaways

The habits to take back to your next lightweight assessment.

Finish

Final quiz and certificate

Ten project scenarios. Pass and the certificate goes straight into your dashboard.

Intermediate. For people who already assess or document lightweight Class 1 houses on the house energy rating pathway. Covers metal framed walls and roofs, thermal breaks and the junctions that bridge in any construction. It does not replace the calculation inside your software or the NatHERS Technical Notes.

Who it is for

Written for the people who put the frame into the model.

Energy assessors

You model lightweight houses from sets that name the cladding, the batts and the lining, and leave the frame blank.

1 hour of technical CPD

Building designers

Framing to engineer’s details on your wall schedule is the line your assessor has to guess at.

1 CPD point, with audit-ready records

Architects

You specify the envelope, and a thermal break only works if your junction details carry it through.

1 formal CPD point

Building surveyors

You check that the construction assessed is the one documented and built, including any break claimed in the model.

1 CPD point

Residential builders

A switch from timber to steel framing changes the rating, and the assessor needs to hear about it before the slab is poured.

1 CPD point, state CPD
How it counts

Where this hour goes on your record.

National Standard of Competency for Architects (NSCA 2021) performance criteria this course aligns with:

PC12

Building codes and standards

PC28

Building science and technology

PC39

Integrating materials and construction

PC45

Materials and performance standards

PC47

Complete and accurate documentation

If you are

How it is recorded

An energy assessor

1 hour of technical CPD on thermal performance and building fabric assessment. Your certificate, the learning outcomes, the module outline and your quiz result are kept in your dashboard for your accrediting organisation’s records.

An architect

1 formal CPD point. Aligned with NSCA 2021 performance criteria PC12, PC28, PC39, PC45 and PC47.

A building designer, surveyor or builder

1 hour of CPD on the thermal bridging provisions of the ABCB Housing Provisions, recorded on your certificate for your registration body or state scheme.

CPD On Demand is not a registered training organisation and courses are not accredited by any registration body. Each course is aligned with the relevant competency frameworks and gives you the records to evidence it. CPD rules differ by registration body and state, so check with yours if you are unsure.

  • Explain why heat leaves a lightweight envelope through the framing rather than the insulation, and why losses concentrate at corners, openings, slab edges and parapets.
  • Identify the metal framed wall and roof provisions in the ABCB Housing Provisions and the two cumulative conditions that trigger a thermal break.
  • Determine which edition of the NCC governs a project and confirm that the thermal bridging provisions read the same in NCC 2022 and NCC 2025.
  • Apply the correct frame and thermal break treatment in a NatHERS model where the construction is documented, and recognise when a break is not required.
  • Write a request for information that names the missing item, the drawing it belongs on, the assumption if unanswered and a date.
  • Maintain an assumptions register and report bridging without overstating what was calculated.
Keep going

Pairs well with.

Energy assessors

When the Spec Doesn’t Say Enough

Turning a specification that exists but says too little into defensible modelling inputs.

Building designers

The Breathable Wall: Understanding Condensation Risks in NCC 2025

The other consequence of a cold surface: condensation inside the wall and roof.

Energy assessors

Designing Thermal Zones for Better NatHERS Performance

Defining and mapping thermal zones so the model reflects how the house is used.

Questions

Before you enrol.

Yes. The thermal bridging provisions read the same in NCC 2022 and NCC 2025, so what you learn applies under either. The course sets out which edition governs in each state and territory, so you cite the right one for the project in front of you.

Start, stop and finish later. Progress is saved and the course stays in your dashboard.

Yes, on passing the final quiz. It is stored in your dashboard alongside your other CPD records.

No. It shows you how to confirm your tool’s behaviour against its own technical documentation and the NatHERS Technical Notes, and how to record an assumption when the frame is not documented. It does not replace the calculation inside your software.

Yes. Team packs start at $579 for six courses shared across your practice.

No. Every course is product neutral. No thermal break brands, no sponsor, no sales pitch at the end.

Get the frame into the model, and into the record, in one self-paced hour.

$99, 60 minutes, certificate on completion.

$99 1 hour, certificate