Your course

Pick up where you left off.

Current Status

Not Enrolled

Price

A$99.00

Get Started

Course Content

I. Introduction (5 minutes)
II. Learning Objectives (2 minutes)
VII. Case Studies (4 minutes)
VIII. Summary & Key Takeaways (2 minutes)
For building designers, architects and building surveyors

The Breathable Wall: Understanding Condensation Risks in NCC 2025

Condensation stays hidden behind the lining until the mould call, two winters after handover.

Understanding condensation risks in NCC 2025. How warm, moist air turns to water inside Class 1 walls and roofs, when a drained and ventilated cavity is mandatory, which membrane class Table 10.8.1 asks for in each climate zone, and what a certifier needs to see on the wall section and in the specification.

60 minutes, self-paced Beginner level 1 formal CPD point Certificate on completion National, NCC 2025 and NCC 2022
Aligned to NSCA 2021 PC12 PC28 PC33 PC45 PC46
$99 inc. GST
  • Product neutral, no supplier content
  • Audio version and glossary included
  • Certificate saved to your dashboard

Secure card checkout. Tax invoice emailed.

Course content

4 modules, 2 case studies, final quiz and certificate.

Start 7 min

Introduction and objectives

Which edition applies where you practise, and what NCC 2025 changed about condensation.

Module 1 9 min

Reading the Risk: How Condensation Forms in Homes

Explain dew point and vapour drive, and find where moisture collects inside a well sealed, well insulated home.

Module 2 10 min

The Ventilated Cavity: Designing Walls That Drain and Breathe

Know when a drained and ventilated cavity is mandatory, and the depth, openings and roof ventilation that make it work.

Module 3 12 min

Choosing the Membrane: Vapour Control by Climate Zone

Read Table 10.8.1 and pick the membrane vapour permeance class for the climate zone and the wall.

Module 4 10 min

Documenting for Approval: Details That Pass First Time

Put the cavity, the membrane class, the openings and the Standards on the section and in the specification a certifier reads.

Case studies 4 min

A cavity at certification and a mould call

A zone seven wall caught at certification, and a cool zone home sealed on both faces. Both are illustrative.

Summary 2 min

Key takeaways

Understand the risk, design the cavity, choose by climate and document to approve.

Finish

Final quiz and certificate

Ten project scenarios across the four learning objectives. Pass and the certificate goes straight into your dashboard.

Beginner. For people who document, build or assess Class 1 homes under Volume Two. Covers condensation physics, drained and ventilated cavities, membrane selection by climate zone, roof ventilation and exhaust discharge, and the documentation a certifier needs, with each figure labelled NCC 2025 or NCC 2022. It does not cover Class 2 to 9 buildings under Volume One Part F8, or energy rating.

Who it is for

Written for the people whose wall section decides whether the house can dry.

Building designers

You document Class 1 homes in Volume Two, and the wrap and cavity on your section decide where moisture goes.

1 CPD point, with audit-ready records

Architects

You carry a standard wall detail across climate zones and need to know where it stops complying.

1 formal CPD point

Building surveyors

You check the cavity, the membrane class and the openings against Part 10.8 before the frame goes up.

1 hour of CPD

Residential builders

You build the cavity and fix the membrane, and a mould call after handover lands on you first.

1 hour of CPD

Energy assessors

Tighter, better insulated homes hold more moisture, so the star rating and the wall have to work together.

1 hour of CPD
How it counts

Where this hour goes on your record.

National Standard of Competency for Architects (NSCA 2021) performance criteria this course aligns with:

PC12

Advice under building codes and standards

PC28

Building science applied to design performance

PC33

Integrating thermal and other environmental systems

PC45

Performance standards for materials and systems

PC46

Documentation that complies with codes

If you are

How it is recorded

A building designer

1 CPD point. Your certificate, the learning outcomes, the module outline and your quiz result are kept in your dashboard, so you can show what you studied if your CPD is audited.

An architect

1 formal CPD point. Aligned with NSCA 2021 performance criteria PC12, PC28, PC33, PC45 and PC46.

A building surveyor, builder or energy assessor

1 hour of CPD on condensation management under NCC 2025 and NCC 2022, recorded on your certificate for your registration body, state scheme or accreditation body.

CPD On Demand is not a registered training organisation and courses are not accredited by any registration body. Each course is aligned with the relevant competency frameworks and gives you the records to evidence it. CPD rules differ by registration body and state, so check with yours if you are unsure.

  • Explain how warm, moist indoor air condenses inside wall and roof assemblies, and where NCC 2025 concentrates the risk.
  • Determine whether NCC 2025 or NCC 2022 applies to a project from its state and approval date.
  • Apply the drained and ventilated cavity requirements, including when a cavity is mandatory.
  • Select the right membrane vapour permeance class for each climate zone using Table 10.8.1.
  • Plan roof space ventilation and exhaust discharge so moisture leaves the building.
  • Prepare wall sections and specifications that give a certifier the evidence needed for first-time approval.
Keep going

Pairs well with.

Building designers

The Waterproofing Time Bomb: Defending High-Risk Balconies and Podiums

The other half of Part F: keeping water out of balconies, podiums and concrete roofs.

Building designers

Insulation Documentation That Gets Approved: What Reviewers Actually Look For

How reviewers read the insulation that sits behind your membrane.

Building designers

Bio-Based Building Materials: Risks, Benefits & Compliance

The same wall provisions applied to hempcrete and straw bale walls.

Questions

Before you enrol.

Yes. Condensation management has been a code requirement since NCC 2022, and every figure in the course is labelled with its edition. NCC 2025 is in force in Victoria. Western Australia and the ACT allow either edition until 1 May 2027, although in the ACT a building approval issued after 1 November 2026 must be under NCC 2025 unless the development application was lodged first. New South Wales, Queensland, South Australia and Tasmania stay on NCC 2022 until 1 May 2027, and the Northern Territory has not adopted NCC 2025. Confirm the edition for each project with your state or territory building authority.

Start, stop and finish later. Progress is saved and the course stays in your dashboard.

Yes, on passing the final quiz. It is stored in your dashboard alongside your other CPD records.

No. It is written for Class 1 homes under Volume Two and the Housing Provisions. Volume One Part F8, which governs Class 2 to 9 buildings, is not covered.

Yes. Team packs start at $579 for six courses shared across your practice.

No. Every course is product neutral. No membrane or wrap brands, no sponsor, no sales pitch at the end.

Design a wall that drains, breathes and passes certification, in one self-paced hour.

$99, 60 minutes, certificate on completion.

$99 1 hour, certificate