Pick up where you left off.
Course Content
Class 2 Apartment Design Compliance for Architects
One separating floor has to stop fire, sound and water at once, and the junction is where it fails.
NCC 2025 compliance for Class 2 apartment buildings, read as one integrated problem. The sole occupancy unit boundary where fire, water, acoustic and amenity provisions meet, the new water management framework for balconies and podiums, acoustic and condensation detailing at the separating element, Livable Housing and accessible common areas, and the record that defends a defect prone building class.

Secure card checkout. Tax invoice emailed.
4 modules, 2 case studies, final quiz and certificate.
Introduction and objectives
Why Class 2 is an integrated compliance problem, and which NCC edition governs an apartment project in each state and territory.
The Class 2 Compliance Landscape
Read the sole occupancy unit boundary as the line where fire, water, acoustic and amenity provisions attach, including at mixed use podiums.
The NCC 2025 Water Management Framework
Set falls in the slab, overflows and membrane placement for balconies and podiums over dwellings, with long term deflection allowed for.
Acoustic, Condensation & the Separating Element
Detail separating walls, floors and services penetrations so airborne, impact and moisture performance survive the junctions.
Livable Housing, Accessibility, Documentation & Risk
Plan Livable Housing and accessible common areas in from the start, and evidence every claim in a record that manages transition risk.
A podium balcony and a penetration
Flush balconies with no room for falls, and a compliant floor that failed its field test at one penetration.
Key takeaways
The five habits that defend an apartment building, from the boundary to the record.
Final quiz and certificate
Ten project scenarios. Pass and the certificate goes straight into your dashboard.
Advanced. For architects who already design and document Class 2 apartment buildings. Covers the Volume One fire, water management, acoustic, condensation, Livable Housing and access provisions where they meet at the separating element, under both NCC 2022 and NCC 2025. It is general guidance, not legal advice, and it does not replace the structural, acoustic or fire engineer’s input.
Written for the people who design, check and build the boundary between apartments.
Architects
You coordinate the separating element where one change for sound can quietly break the fire rating or the fall.
Building designers
You document apartment and mixed use work where a missed junction becomes a defect claim later.
Building surveyors
You assess whether the Class 2 set evidences fire, water, acoustic and access compliance under the right edition.
Structural engineers
Falls in the slab and long term deflection now decide whether a balcony keeps water out.
Licensed builders
You build the penetrations, upstands and resilient layers that decide whether the tested system performs.
Where this hour goes on your record.
National Standard of Competency for Architects (NSCA 2021) performance criteria this course aligns with:
Advice under building codes and standards
Materials with structure and construction
Coordinating consultant input
Documentation that complies with codes
Accurate documents for stakeholders
|
If you are |
How it is recorded |
|---|---|
|
An architect |
1 formal CPD point. Aligned with NSCA 2021 performance criteria PC12, PC39, PC41, PC46 and PC47. |
|
A building designer |
1 CPD point. Your certificate, the learning outcomes, the module outline and your quiz result are kept in your dashboard, so you can show what you studied if your CPD is audited. |
|
A building surveyor, engineer or builder |
1 hour of CPD on Class 2 compliance under NCC 2022 and NCC 2025, recorded on your certificate for your registration body or state scheme. |
CPD On Demand is not a registered training organisation and courses are not accredited by any registration body. Each course is aligned with the relevant competency frameworks and gives you the records to evidence it. CPD rules differ by registration body and state, so check with yours if you are unsure.
Pairs well with.
Balcony Waterproofing Under NCC 2025: What Has Actually Changed (and What Hasn’t)
Module 2 in depth: the fall, the step down and the hob at the slab.
Fire Safety in Class 2 to 9 Buildings for Architects
The fire side of the same building: construction type, compartments and egress.
NCC 2025 for Architects: Commercial and Apartment Buildings
Everything else the new edition changed in Volume One.
Before you enrol.
Detail the apartment boundary so fire, water and sound all hold, in one self-paced hour.
$99, 60 minutes, certificate on completion.