Your course

Pick up where you left off.

Current Status

Not Enrolled

Price

$99.00

Get Started

Course Content

I. Introduction (4 minutes)
II. Learning Objectives (1 minute)
IV. Module 2: The Certified System, Not the Look-Alike (11 minutes)
V. Module 3: Substitution and Your Exposure (11 minutes)
VI. Module 4: Installing So the Rating Is Preserved (11 minutes)
VII. Case Studies (4 minutes)
VIII. Summary and Key Takeaways (2 minutes)
Final Quiz – Fire and Combustibility for Cladding Installers
For cladding and facade installers, builders, site supervisors and certifiers

Fire and Combustibility for Cladding Installers

When the panel on the wall is not the panel on the certificate, your name is on the docket.

Which external walls must be non-combustible, what that word means as a laboratory test rather than a look, and which documents prove a panel passed it. How a substitution breaks compliance without anyone noticing, what to put in writing before the pallet is opened, and how to install and photograph the certified system so its rating survives an audit years later.

60 minutes, self-paced Intermediate level 1 formal CPD point Certificate on completion National, NCC 2025 and NCC 2022
Aligned to NSCA 2021 PC12 PC16 PC45 PC55 PC56
$99 inc. GST
  • Product neutral, no supplier content
  • Audio version and glossary included
  • Certificate saved to your dashboard

Secure card checkout. Tax invoice emailed.

Course content

4 modules, 2 case studies, final quiz and certificate.

Start 5 min

Introduction and objectives

Why a combustible facade bypasses every fire measure inside the building, and why the installer now sits inside the chain of responsibility.

Module 1 11 min

What Non-Combustible Means and Where It Applies

Read Type A or B off the class and rise in storeys, tell an AS 1530.1 result from early fire hazard indices, and know the short list of what may be combustible.

Module 2 11 min

The Certified System, Not the Look-Alike

Check a test report against the panel, core, framing, insulation and sarking, and run the four-way match on delivery day.

Module 3 11 min

Substitution and Your Exposure

Answer an offered or delivered substitute in writing, stop the affected work until the certifier confirms, and record what you fitted on whose instruction.

Module 4 11 min

Installing So the Rating Is Preserved

Fix every layer mechanically, check cavity barriers, junctions and penetrations against the system, and photograph each elevation before cover.

Case studies 4 min

One installer protected, one exposed

Two facades picked up in state audits: one cleared from the installer’s folders, one ordered off the building with the installer named.

Summary 2 min

Key takeaways

The five habits to take to your next facade, from reading the drawings to signing only for what you fitted.

Finish

Final quiz and certificate

Ten scenario questions from real facade decisions. Pass and the certificate goes straight into your dashboard.

Intermediate. For people who install, supervise, supply or certify external walls on Class 2 to 9 buildings. Covers the non-combustible external wall provisions of NCC Volume One, evidence of suitability, substitution and installing to the tested system, with state cladding bans and duties stated by state. It does not cover fire engineering, the choice of construction type or performance solutions, which belong to the designer, the fire engineer and the certifier, and it is not legal or insurance advice.

Who it is for

Written for everyone between the specification and the finished facade.

Cladding and facade installers

You fit what is delivered, and years later an audit sample decides whether it was the product on the certificate.

1 hour of CPD, certificate on file

Licensed builders and site supervisors

A buyer’s cheaper equal or a signed site instruction is where a certified facade quietly stops being one.

1 CPD point, state CPD

Building surveyors and certifiers

You accept a product on its evidence, and every inspection after that assumes it is what went on the wall.

1 CPD point

Architects and facade designers

Only you and the certifier can accept a substitution, and the installer’s written note is how it reaches you.

1 formal CPD point for architects

Building product suppliers and estimators

A sister panel or a cheaper equal usually starts with you, and in Queensland so do chain of responsibility duties.

1 hour of professional development
How it counts

Where this hour goes on your record.

National Standard of Competency for Architects (NSCA 2021) performance criteria this course aligns with:

PC12

NCC fire provisions and standards

PC16

Liability exposure and risk mitigation

PC45

Materials and performance standards

PC55

Construction phase records

PC56

Substitution control and rectification

If you are

How it is recorded

A cladding or facade installer

1 hour of CPD on the NCC non-combustible external wall provisions, evidence of suitability and installation records. Your certificate, the learning outcomes, the module outline and your quiz result are kept in your dashboard for your licence or employer records.

An architect

1 formal CPD point. Aligned with NSCA 2021 performance criteria PC12, PC16, PC45, PC55 and PC56.

A builder, site supervisor or certifier

1 hour of CPD on the NCC Volume One fire provisions for external walls, recorded on your certificate for your registration body or state scheme.

CPD On Demand is not a registered training organisation and courses are not accredited by any registration body. Each course is aligned with the relevant competency frameworks and gives you the records to evidence it. CPD rules differ by registration body and state, so check with yours if you are unsure.

  • Identify which buildings and which external wall components must be non-combustible under NCC Volume One, reading the trigger from class and rise in storeys.
  • Distinguish combustibility to AS 1530.1 from the early fire hazard indices of AS/NZS 1530.3, and both from the marketing term fire retardant.
  • Read the evidence of suitability for a cladding system and judge whether it covers the exact product, thickness and core delivered to site.
  • Apply the four-way match across docket, order, specification and certificate before a panel leaves the pallet.
  • Respond to a proposed or discovered substitution by raising it in writing, stopping the affected work and waiting for the certifier.
  • Install a certified system so its tested rating survives, with mechanical fixing, cavity barriers and a located photographic record before cover.
Keep going

Pairs well with.

Building designers

Non-Conforming Building Products: Specification Risk, Evidence of Suitability, and Documentation Defence for Building Designers

Evidence of suitability and substitution, from the specifier’s side of the same chain.

Builders, designers and surveyors

Fire Safety in Residential Design: Understanding Passive and Active Systems for Design Documentation and Coordination

Passive and active fire systems, fire stopping and penetrations, coordinated with the fire engineer and certifier.

Builders, designers and surveyors

How the NCC Actually Works: Structure, Responsibility & Compliance Pathways (Understanding NCC 2022 and What the NCC 2025 Preview Means for Practice)

Deemed-to-Satisfy, Verification Methods and Performance Solutions, and who is responsible for each.

Questions

Before you enrol.

Yes. The non-combustible external wall provisions the course teaches read the same in NCC 2022 and NCC 2025. The one change NCC 2025 makes is that the combustibility and fire hazard tests must be determined by an Accredited Testing Laboratory, with a transition period. State cladding bans and installer duties differ, so the course states them by state and you confirm them for your project.

Start, stop and finish later. Progress is saved and the course stays in your dashboard.

Yes, on passing the final quiz. It is stored in your dashboard alongside your other CPD records.

No. It teaches what the installer fits, checks, refuses and records. The choice of construction type, fire engineering and any performance solution belong to the designer, the fire engineer and the certifier. How Deemed-to-Satisfy provisions, Verification Methods and Performance Solutions fit together is covered in How the NCC Actually Works.

Yes. Team packs start at $579 for six courses shared across your business.

No. Every course is product neutral. No cladding panel brands, no sponsor, no sales pitch at the end.

Fit the certified system, and keep the record that proves it, in one self-paced hour.

$99, 60 minutes, certificate on completion.

$99 1 hour, certificate